Measure first, buy a listed storage heater that fits the closet and the fuel you already have, then reconnect the pan and the relief drain.
- Read both labelsCopy the model and fuel type from the old heater, and the manufacturer, serial, and date from the home’s data plate. Those two labels answer different questions.
- Measure the compartmentWrite down height, width, depth, which side the pipes are on, and the size of the access opening. Include the flue collar if the vent leaves the top.
- Match fuel and listingStay with the fuel you have unless an electrician and, for gas, a qualified fitter are changing the hookup. Buy a storage heater the manual lists for manufactured housing.
- Confirm the door and the airA vented exterior door feeds combustion air on many atmospheric gas heaters. A solid door is not a substitute. Direct-vent heaters use the inlet that came with the appliance.
- Set the pan and the relief lineThe drip pan has to drain outside or to a drain. The temperature and pressure relief valve needs its own full-size line to the outside, ending where you can see it.
- Stop if the flue, gas line, or circuit is unclearReusing an old roof jack, capping gas, or upsizing a breaker is the part most owners should hire. Water on the floor from a previous leak is a separate repair.
A manufactured home water heater fails in a tight closet, often on a weekend, and the heater at the big-box store is frequently the wrong one. These homes were built to the federal HUD standards. The replacement has to follow the appliance’s listing, fit the compartment you already have, and put leaking water outside the house instead of into the floor.
People say “mobile home” for all of these houses. In the rules, a mobile home was built before June 15, 1976, and a manufactured home was built to the HUD Code on or after that date. The shopping problem is similar either way: measure the space you have, and do not assume a site-built heater will drop in.
Buy a listed storage heater
Heat-producing appliances in manufactured homes, including the vents and roof jacks they need, must be listed or certified for residential use by a nationally recognized testing agency. That is 24 CFR 3280.707. The installation also has to follow the appliance’s own instructions, and the heater has to be secured, accessible, and removable for service. That is 24 CFR 3280.709(a).
In a store aisle, the practical test is simpler. The carton, the spec sheet, or the manual should say the heater is for manufactured housing, or show that it was evaluated to the HUD standard. If a seller cannot point to that, treat it as the wrong heater even when the gallon size looks right. Verify the listing for the exact model you are about to buy. Model numbers change.
Electric, gas, and tankless
Electric storage heaters do not need combustion air. They do need a circuit that matches the heater. Read the voltage and wattage on the old plate and the new one, and do not put a heater on a breaker the listing does not allow. If you cannot compare those plates to the breaker, that is a short electrician visit.
Gas is different. Fuel-burning appliances, other than ranges, ovens, dryers, and a few exceptions, have to keep combustion air separated from the air inside the home. See 24 CFR 3280.709(d). That is either a direct-vent appliance, or a heater in an enclosure that opens outdoors and has no door back into the living space. Pipe and wire openings into that enclosure are supposed to be sealed.
Atmospheric gas heaters for these homes exist. One Performance sheet lists 29 and 40 gallon natural-gas models and says they are CSA and HUD certified, with roof jacks available. Do not reuse an old roof jack because it looks close. The new manual has to list it. Switching fuels or capping a gas line needs a permit and someone qualified.
Tankless heaters are not a casual upgrade. HUD told its inspection agencies that tankless water heaters do not meet the standards as written, and that a factory would need an Alternative Construction approval. The letter is on HUD’s site. Plan on another listed storage heater unless someone qualified is obtaining that approval.
Sizes that show up on spec sheets
There is no single gallon size. A Rheem Warrior electric sheet for manufactured housing lists 20, 30, 40, and 50 gallon models. The gas sheet above lists 29 and 40 gallons. Other brands publish other sizes. The sheets show that listed sizes exist. They do not show that one fits your closet. A shorter “side connect” heater is common because the compartment is short. Match the connection side you actually have, and use the recovery numbers printed on the model you buy.
Measure the compartment before you order
Write these down with the tape, not from memory:
- Inside height, and the height of the opening you have to pass the heater through.
- Width and depth. Include the flue collar if it sticks up, and any fitting that sticks out the side.
- Which side the cold inlet, hot outlet, and relief valve are on.
- Electric: volts and watts from the plate, and the breaker number. Gas: input rating, and any model stamped on the roof jack.
- Whether the compartment door opens outdoors, indoors, or both. A fuel-burning heater generally should not have an opening back into the house.
- Whether a pan is already there, and whether you can see its drain outside.
The compartment is not storage. 24 CFR 3280.709(c) tells the manufacturer to guard the area or to post a warning, because combustibles next to the heater are a fire hazard. Take the boxes back out.
The access door is its own part
Many older homes reach the heater through a tall exterior door, sold by the rough opening. Sellers list widths around 20, 22, and 23 inches at 60 inches tall. Elixir publishes a 20 by 60 panel as a standard size. One retail listing describes a vented 23 by 60 door as stud to stud. Another lists 22 by 60 and 23 by 60, vented or solid. Those are catalog sizes. Measure stud to stud and sill to header. Measuring only the old slab is how the wrong door gets ordered. Verify the size against that seller’s chart.
Vented versus solid follows the heater. Atmospheric gas units that take combustion air through the door need the vents. A solid door can starve that burner. Direct-vent and electric heaters are a different case. Match the door to the manual. A draft hood under a roof jack usually means atmospheric. A sealed vent kit means direct vent. The data plate may name the original heater. The label on the tank is the one to match if it has already been replaced.
Pan, relief valve, and water pressure
A corrosion-resistant drip pan is required under each storage tank-type water heater, drained to the exterior of the home or to a drain. That is 24 CFR 3280.709(h). A pan with no drain, or a drain that ends in the belly insulation, is how a slow leak becomes a soft floor.
The relief valve has its own rules in 24 CFR 3280.609(c). Discharge is piped full size, not into a drain, by gravity, with no trap, and the end is not threaded. Outside, it points down and ends 6 to 24 inches above grade, where you can see it. It does not dump under the home. Do not plug the outlet because the line is annoying.
The same section says the home was designed for 80 psi inlet pressure, and that a pressure-reducing valve belongs where street pressure is higher. If the relief valve drips, check pressure with a gauge before you blame the tank.
If the home is in Florida
Many Florida park homes are all-electric. Yours may not be. Read the plate. A pan that drains under the home soaks the belly, and skirting is not allowed to leave heater drains standing there. The wind zone on the data plate does not change the gallon size. It does mean the roof jack and the exterior door get fastened the way their listings say.
Where to buy, and what not to buy
Mobile Home Parts Store and Fulton MHP carry listed heaters, roof jacks, and access doors. Ask for the delivered price. A tank is a freight item.
Amazon is fine for a drain pan or an element once you have the part number off the heater you own. It is a poor place to grab the first water heater in the search results. If the listing does not say manufactured housing, skip it. Keep the old heater until the new one heats. If the floor is already soft, fix the leak path and then the floor.
Questions people ask
Can I install a regular residential water heater in a mobile home?
Plan on a storage water heater whose listing and manual are for manufactured housing. A site-built heater can be the wrong shape, the wrong vent, and the wrong listing. Heat-producing appliances in these homes have to be listed or certified for residential use, and the installation has to follow that listing.
What size is a mobile home water heater door?
There is no single size. Sellers commonly list tall exterior access doors around 20, 22, and 23 inches wide by 60 inches tall, vented or solid. Measure the framed opening, stud to stud and sill to header, and match the seller’s chart. Verify the size for your home.
Does a manufactured home water heater need a drain pan?
Yes for a storage tank. Federal rules require a corrosion-resistant drip pan under each storage tank-type water heater, drained to the outside of the home or to a drain. The pan only helps if the drain line actually leaves the crawl space.
Can I replace the tank with a tankless water heater?
HUD has told its inspection agencies that tankless water heaters do not meet the manufactured home standards as written. Installing one takes an Alternative Construction approval. A homeowner replacing a failed tank should plan on another listed storage heater unless a qualified party is handling that approval.
Sources
- 24 CFR 3280.609, water distribution systems — eCFR
- 24 CFR 3280.707, heat producing appliances — eCFR
- 24 CFR 3280.709, installation of appliances — eCFR
- HUD letter on tankless water heaters and Alternative Construction — U.S. Department of Housing and Urban Development
- Rheem Warrior electric water heater sheet for manufactured housing — Product literature
- Performance atmospheric gas water heaters for manufactured housing — Product literature
- Elixir water heater access panels — Elixir Door and Metals
- Example 23 by 60 inch vented access door — RV Parts Home